Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 57
Page
... Stairs and Exits 605. Light and Ventilation 606. Enclosure of Vertical Openings Fire Extinguishing Apparatus Special Hazards 607 . 608 . 609 . 610 . Exceptions and Deviations Mixed Occupancies CHAPTER 7. Requirements for Group B ...
... Stairs and Exits 605. Light and Ventilation 606. Enclosure of Vertical Openings Fire Extinguishing Apparatus Special Hazards 607 . 608 . 609 . 610 . Exceptions and Deviations Mixed Occupancies CHAPTER 7. Requirements for Group B ...
Page 21
... stair four ( 4 ) feet or more in width , and on one side of each stair- way three feet six inches ( 3 ′ 6 ′′ ) or less in width . Stairs emptying into exit courts shall meet the court floor at not less than the stair width from the near ...
... stair four ( 4 ) feet or more in width , and on one side of each stair- way three feet six inches ( 3 ′ 6 ′′ ) or less in width . Stairs emptying into exit courts shall meet the court floor at not less than the stair width from the near ...
Page 30
... stairs or ramps need not be enclosed when stairs lead directly to the outer air or are connected thereto by direct passages with unpierced walls and ceilings . All emergency stairs and ramps shall lead di rectly to a public street or ...
... stairs or ramps need not be enclosed when stairs lead directly to the outer air or are connected thereto by direct passages with unpierced walls and ceilings . All emergency stairs and ramps shall lead di rectly to a public street or ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood