Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 83
Page 31
... Type I 75 ft . Type II 55 ft . 65 ft . NO RESTRICTIONS 7 stories 12,000 15,000 18,000 5 stories 15,000 18,000 20,000 66 2-3 % 1 story 20,000 25,000 30,000 Type III 55 ft . 20 ft . 5 stories 12,000 15,000 18,000 1 story 18,000 22,000 ...
... Type I 75 ft . Type II 55 ft . 65 ft . NO RESTRICTIONS 7 stories 12,000 15,000 18,000 5 stories 15,000 18,000 20,000 66 2-3 % 1 story 20,000 25,000 30,000 Type III 55 ft . 20 ft . 5 stories 12,000 15,000 18,000 1 story 18,000 22,000 ...
Page 56
... Type of Construction , it is necessary that all of the requirements for that Type of Construction be complied with . No building or portion thereof shall be required to conform to the details of a Type of Construction higher than that ...
... Type of Construction , it is necessary that all of the requirements for that Type of Construction be complied with . No building or portion thereof shall be required to conform to the details of a Type of Construction higher than that ...
Page 72
... Type I , II , III or IV building shall be considered to be of Type V. Height Sec . 2202. Type V buildings shall not exceed a height of Allowable thirty - five ( 35 ) feet in which height there shall be not more than three ( 3 ) stories ...
... Type I , II , III or IV building shall be considered to be of Type V. Height Sec . 2202. Type V buildings shall not exceed a height of Allowable thirty - five ( 35 ) feet in which height there shall be not more than three ( 3 ) stories ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood