Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 70
Page
... Allowable 703. Location on Property 704. Stairs and Exits 705. Light and Ventilation 706. Enclosure of Vertical Openings 707. Fire Extinguishing Apparatus 708. Special Hazards 709. Exceptions and Deviations 710. Mixed Occupancies ...
... Allowable 703. Location on Property 704. Stairs and Exits 705. Light and Ventilation 706. Enclosure of Vertical Openings 707. Fire Extinguishing Apparatus 708. Special Hazards 709. Exceptions and Deviations 710. Mixed Occupancies ...
Page
... Allowable 1003 . Area Allowable 2004 . Foundations 2005 . 2006 . Exterior and Inner Court Walls Partitions 2007. Enclosure of Vertical Openings Structural Framework 2008 . 2009. Fireproofing Structural Members 2010. Floor Construction ...
... Allowable 1003 . Area Allowable 2004 . Foundations 2005 . 2006 . Exterior and Inner Court Walls Partitions 2007. Enclosure of Vertical Openings Structural Framework 2008 . 2009. Fireproofing Structural Members 2010. Floor Construction ...
Page 252
... allowable Bays and balconies .. 1903 .1914 , 3501 Combustible materials - regulated Cornices 1914 , 1916 1914 , 4501 Definition of 1901 Doors and windows .. .1913 , 3401 Exterior openings - protection of .. 1913 Fireproofing - may be ...
... allowable Bays and balconies .. 1903 .1914 , 3501 Combustible materials - regulated Cornices 1914 , 1916 1914 , 4501 Definition of 1901 Doors and windows .. .1913 , 3401 Exterior openings - protection of .. 1913 Fireproofing - may be ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood