Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 34
Page 174
... chimney nor shall such chimneys be used for fire- places . When such chimneys are erected on the outside of a build ... chimney for the purpose of cleaning the flue . All patent chimneys shall be built plumb and without bends . All ...
... chimney nor shall such chimneys be used for fire- places . When such chimneys are erected on the outside of a build ... chimney for the purpose of cleaning the flue . All patent chimneys shall be built plumb and without bends . All ...
Page 175
... chimney as spec- ified in Section 3701 . All fireplaces and chimney breasts shall have trimmer arches or other approved fire - resistive construction supporting hearths . The arches and hearths shall be not less than twenty ( 20 ) ...
... chimney as spec- ified in Section 3701 . All fireplaces and chimney breasts shall have trimmer arches or other approved fire - resistive construction supporting hearths . The arches and hearths shall be not less than twenty ( 20 ) ...
Page 233
... chimney Of stucco reinforcement 2507 ( h ) 2205 ( c ) Requirements in wood frame construction FUSIBLE LINKS .2510 ( b ) For automatic sprinkler systems For doors - automobile ramp enclosures 3802 1006 For fire doors For horizontal exits ...
... chimney Of stucco reinforcement 2507 ( h ) 2205 ( c ) Requirements in wood frame construction FUSIBLE LINKS .2510 ( b ) For automatic sprinkler systems For doors - automobile ramp enclosures 3802 1006 For fire doors For horizontal exits ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood