Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 89
Page 64
... floor or balcony , fireproofing of all members of the roof construction may be omitted . ( 4 ) Where the structural steel framework of the roof of a Group A , B or C building is more than eighteen ( 18 ) feet and less than twenty - five ...
... floor or balcony , fireproofing of all members of the roof construction may be omitted . ( 4 ) Where the structural steel framework of the roof of a Group A , B or C building is more than eighteen ( 18 ) feet and less than twenty - five ...
Page 82
... floor area shall be permitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as ware- houses or for storage ...
... floor area shall be permitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as ware- houses or for storage ...
Page 159
... floor Cor- eling of masonry walls under floor planks may be used in place f such molding . If laminated floors are used , at least two laminations at the vall shall be omitted until after glazing and roofing has been ompleted ...
... floor Cor- eling of masonry walls under floor planks may be used in place f such molding . If laminated floors are used , at least two laminations at the vall shall be omitted until after glazing and roofing has been ompleted ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood