Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 39
Page 78
... joists shall have a clearance of not less than twelve ( 12 ) inches between the bottom of the joists and the surface of the ground underneath . ( See Appendix - Section 2511. ) Joists under bearing partitions shall be installed as speci ...
... joists shall have a clearance of not less than twelve ( 12 ) inches between the bottom of the joists and the surface of the ground underneath . ( See Appendix - Section 2511. ) Joists under bearing partitions shall be installed as speci ...
Page 103
... joists that run parallel to the wall . ( g ) The minimum permissible thickness of joists , rafters and studs shall be one and five - eights ( 1-5 / 8 ) inches . ( h ) Floor joists shall be supported by girders , bearing par- titions or ...
... joists that run parallel to the wall . ( g ) The minimum permissible thickness of joists , rafters and studs shall be one and five - eights ( 1-5 / 8 ) inches . ( h ) Floor joists shall be supported by girders , bearing par- titions or ...
Page 138
... joists shall not exceed those specified in Section 2702 and no joist under its calculated load shall have a deflection exceeding one three - hundred - sixtieth ( 1/360 ) of the span . Bridging shall be ... joist or joists 138 Sec . 2714.
... joists shall not exceed those specified in Section 2702 and no joist under its calculated load shall have a deflection exceeding one three - hundred - sixtieth ( 1/360 ) of the span . Bridging shall be ... joist or joists 138 Sec . 2714.
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood