Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 39
Page 19
... located the main entrance and exit of Property such building . The main floor of every Group A occupancy shall be located at or near the ground floor level . All exterior walls or parts of walls , except on street fronts , of Group A ...
... located the main entrance and exit of Property such building . The main floor of every Group A occupancy shall be located at or near the ground floor level . All exterior walls or parts of walls , except on street fronts , of Group A ...
Page 26
... located at or near ground floor level , in which case all exits shall be at street level or shall meet street level ... located the main entrance and exit of such building , or such building may be connected to the street by an entrance ...
... located at or near ground floor level , in which case all exits shall be at street level or shall meet street level ... located the main entrance and exit of such building , or such building may be connected to the street by an entrance ...
Page 182
... located that any portion of the building can be reached therefrom with a hose not exceeding seventy - five ( 75 ) feet in length . Location . The location of all interior wet standpipes shall be approved by the Building Inspector ...
... located that any portion of the building can be reached therefrom with a hose not exceeding seventy - five ( 75 ) feet in length . Location . The location of all interior wet standpipes shall be approved by the Building Inspector ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood