Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 53
Page 17
... one hour fire - resistive doors as specified in Section 4304 ( a ) . Such doors shall be kept normally closed . The total width of all openings in any vertical " Special Fire Separation " shall not exceed in any one story twenty - five ...
... one hour fire - resistive doors as specified in Section 4304 ( a ) . Such doors shall be kept normally closed . The total width of all openings in any vertical " Special Fire Separation " shall not exceed in any one story twenty - five ...
Page 54
... one - hour fire - resistive construction as specified in Section 4304 . Exceptions : The provisions of paragraph ( g ) shall not apply to doors , windows or other openings which face directly upon and are not within fifty ( 50 ) feet of ...
... one - hour fire - resistive construction as specified in Section 4304 . Exceptions : The provisions of paragraph ( g ) shall not apply to doors , windows or other openings which face directly upon and are not within fifty ( 50 ) feet of ...
Page 60
... one- hour fire - resistive construction or shall have one - hour fire - re- sistive windows as specified in Chapters 36 and 43 . Skylights shall be constructed of one - hour fire - resistive ma- terials as specified in Chapter 43 and in ...
... one- hour fire - resistive construction or shall have one - hour fire - re- sistive windows as specified in Chapters 36 and 43 . Skylights shall be constructed of one - hour fire - resistive ma- terials as specified in Chapter 43 and in ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood