Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 69
Page 21
... side of and not less than one - half the length of the auditorium from the foyer , shall be provided on the main floor of each Group A building . These exits shall be proportioned on the basis of not less than twenty - two ( 22 ) inches ...
... side of and not less than one - half the length of the auditorium from the foyer , shall be provided on the main floor of each Group A building . These exits shall be proportioned on the basis of not less than twenty - two ( 22 ) inches ...
Page 163
... side and handrails shall be placed on at least one side of every stairway and for stairways exceed- ing forty - four ( 44 ) inches in width shall have handrails placed on each side . Stairways over seven ( 7 ) feet wide shall be pro ...
... side and handrails shall be placed on at least one side of every stairway and for stairways exceed- ing forty - four ( 44 ) inches in width shall have handrails placed on each side . Stairways over seven ( 7 ) feet wide shall be pro ...
Page 196
... side construction . One Icell in wall thickness . Plastered . 7 or 5 * 45 4 * Clay Hollow Tile Wall End or side construction . Two cells in 8 - inch or 6 - inch thickness . Unplastered 6 * 16 12 10 or 8 End or side construction Two ...
... side construction . One Icell in wall thickness . Plastered . 7 or 5 * 45 4 * Clay Hollow Tile Wall End or side construction . Two cells in 8 - inch or 6 - inch thickness . Unplastered 6 * 16 12 10 or 8 End or side construction Two ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood