Uniform Building CodePacific Coast Building Officials Conference, 1927 - Building laws |
From inside the book
Results 1-3 of 59
Page 20
... width and shall open directly upon a street into an open court or space not less than ten ( 10 ) feet width which shall be directly connected to a street . One such exit on a street front which shall serve as the ma entrance shall be ...
... width and shall open directly upon a street into an open court or space not less than ten ( 10 ) feet width which shall be directly connected to a street . One such exit on a street front which shall serve as the ma entrance shall be ...
Page 21
... width to each one hundred fifty ( 150 ) seats or major fraction thereof on the main floor of the auditorium , and this exit width shall be equally divided to each side of the auditorium . All such exits shall open directly upon a street ...
... width to each one hundred fifty ( 150 ) seats or major fraction thereof on the main floor of the auditorium , and this exit width shall be equally divided to each side of the auditorium . All such exits shall open directly upon a street ...
Page 116
... width not less than the width of the beam and making an angle of 45 deg . or more with the horizontal , the span may be measured from the section where the combined depth of the beam and bracket is at least one - third ( 1/3 ) more than ...
... width not less than the width of the beam and making an angle of 45 deg . or more with the horizontal , the span may be measured from the section where the combined depth of the beam and bracket is at least one - third ( 1/3 ) more than ...
Other editions - View all
Common terms and phrases
asbestos balconies bars beams block or tile brick Building Inspector building or structure cent Chapter 43 chimney Code column combustible compression compression member construction as specified doors Douglas Fir dry standpipes Enclosure of Vertical exceed exterior walls Fire Zone fireproofed floor area floor construction foot frame girders Group A buildings Group H Gunite gypsum height horizontal inches in thickness inches thick incombustible materials joists less than one-hour less than three live load located masonry walls maximum metal mortar occupancy one-half one-hour fire-resistive construction partitions permit plaster Pondosa Portland cement pounds per square proscenium protected ramps reinforced concrete rivets seats side slabs smoke pipe smokeproof tower solid masonry space specified in Chapter specified in Section square feet square inch Stairs and Exits stairways stories street structural steel studs supported thereof tion twelve 12 twenty 20 Type of Construction Type V buildings ventilation Vertical Openings width wire wood