Page 110
Pacific Coast Building Officials Conference. Bolted Joints WHERE n = allowable unit stress on inclined surface , pounds per square inch . p allowable compressive unit stress ... BOLTS 110 Sections 2507-2508 UNIFORM BUILDING CODE Bolted ...
Pacific Coast Building Officials Conference. Bolted Joints WHERE n = allowable unit stress on inclined surface , pounds per square inch . p allowable compressive unit stress ... BOLTS 110 Sections 2507-2508 UNIFORM BUILDING CODE Bolted ...
Page 111
Pacific Coast Building Officials Conference. TABLE NO 25 - C - HOLDING POWER OF BOLTS Loads Parallel to Grain ( p ) Bolted Joints ( Cont'd . ) LENGTH OF BOLT DIAMETER OF BOLT ( INCHES ) IN MAIN MEM- BER * ( Inches ) 1/2 5 % 3/4 8 1 1 ...
Pacific Coast Building Officials Conference. TABLE NO 25 - C - HOLDING POWER OF BOLTS Loads Parallel to Grain ( p ) Bolted Joints ( Cont'd . ) LENGTH OF BOLT DIAMETER OF BOLT ( INCHES ) IN MAIN MEM- BER * ( Inches ) 1/2 5 % 3/4 8 1 1 ...
Page 112
Pacific Coast Building Officials Conference. Bolted Joints ( Cont'd . ) Timber Connectors sixteenth inch ( 1/16 ′′ ) larger than the bolt , in which case al- lowable loads shall be reduced 10 per cent . ( j ) Bolt Hole Spacing . " Row of ...
Pacific Coast Building Officials Conference. Bolted Joints ( Cont'd . ) Timber Connectors sixteenth inch ( 1/16 ′′ ) larger than the bolt , in which case al- lowable loads shall be reduced 10 per cent . ( j ) Bolt Hole Spacing . " Row of ...
Contents
Part IAdministrative | 19 |
CHAPTER 3 | 25 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
approved bars beams bolt Bolted Joints brick Building Official building or structure ceiling cent Chimneys Code columns combustible compression members compressive strength conform Cont'd designed diameter Douglas fir dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected fire-resistive protection flange floor area floors and roof foot frame girders grade Group grout gypsum horizontal incombustible materials interior joints joists lath least less than one-hour live load located lumber maximum metal minimum mortar Occupancy Separation occupant load one-half inch one-hour fire-resistive construction partitions permitted piles pipe plaster plate portland cement pounds per square proscenium reinforced concrete resist rivets shafts shear six inches slab space span specified in Chapter specified in Section square feet square inch Stairs stairway standpipes Structural P.&T structural steel studs Table tensile stress thickness twenty feet 20 Types of Construction U.B.C. Standard vent ventilation vertical openings width wire wood