Uniform Building Code, Volume 3International Conference of Building Officials, 1952 - Building laws |
From inside the book
Results 1-3 of 15
Page 527
... carbon dioxide into any enclosed space , with dilution of the air to the point where fire is extinguished . ( 2 ) Local Application . ( Class B Systems ) In systems of this class carbon dioxide is applied directly to the fire . ( 3 ) ...
... carbon dioxide into any enclosed space , with dilution of the air to the point where fire is extinguished . ( 2 ) Local Application . ( Class B Systems ) In systems of this class carbon dioxide is applied directly to the fire . ( 3 ) ...
Page 528
... carbon dioxide if the hazard is localized or enclosed . Attention is called , however , to the fact that carbon dioxide protection is especially adapted to extin- guishment of fires in flammable liquids used in the open as local hazards ...
... carbon dioxide if the hazard is localized or enclosed . Attention is called , however , to the fact that carbon dioxide protection is especially adapted to extin- guishment of fires in flammable liquids used in the open as local hazards ...
Page 541
... carbon dioxide system or by automatic sprinkler or other suitable type of protec- tion . It may be desirable to extinguish relatively small , local hazards within this space by local , direct application of carbon dioxide . If the ...
... carbon dioxide system or by automatic sprinkler or other suitable type of protec- tion . It may be desirable to extinguish relatively small , local hazards within this space by local , direct application of carbon dioxide . If the ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood