Page 89
... cent ... Magnesium oxide , minimum , per cent .. Calcium and magnesium oxides , minimum , per cent ... 75 20 95 95 Silica , alumina , and oxide of iron , maxi- mum , per cent . Carbon dioxide , maximum , per cent : If sample is taken at ...
... cent ... Magnesium oxide , minimum , per cent .. Calcium and magnesium oxides , minimum , per cent ... 75 20 95 95 Silica , alumina , and oxide of iron , maxi- mum , per cent . Carbon dioxide , maximum , per cent : If sample is taken at ...
Page 247
... cent of those in Tables 8 , 9 , and 10 . ( b ) When the duration of full maximum load does not exceed the period indicated , increase the allowable unit stresses in Tables 8 and 10 as follows : 15 per cent for two months ' duration , as ...
... cent of those in Tables 8 , 9 , and 10 . ( b ) When the duration of full maximum load does not exceed the period indicated , increase the allowable unit stresses in Tables 8 and 10 as follows : 15 per cent for two months ' duration , as ...
Page 304
... cent .... Aluminum oxide ( Al , Os ) , max . , per cent ... Ferric oxide ( FeO3 ) , max . , per cent . Magnesium oxide ( MgO ) , max . , per cent ... Sulfur trioxide ( SO . ) , max . , per cent ...... Loss on ignition , max . , per cent ...
... cent .... Aluminum oxide ( Al , Os ) , max . , per cent ... Ferric oxide ( FeO3 ) , max . , per cent . Magnesium oxide ( MgO ) , max . , per cent ... Sulfur trioxide ( SO . ) , max . , per cent ...... Loss on ignition , max . , per cent ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood