Page 99
... concrete shall be dry , soft wood , uniform and clean in appearance . They shall pass a one - inch ( 1 " ) screen and shall be not more than one - sixteenth inch ( " ) in thickness . 2-1 . Classification . Gypsum concrete shall be ...
... concrete shall be dry , soft wood , uniform and clean in appearance . They shall pass a one - inch ( 1 " ) screen and shall be not more than one - sixteenth inch ( " ) in thickness . 2-1 . Classification . Gypsum concrete shall be ...
Page 348
... concrete , a time less than one and one - half hours may be specified by the purchaser . When a truck mixer is used for the com- plete mixing of the concrete , the mixing operation shall be- gin within 30 minutes after the cement has ...
... concrete , a time less than one and one - half hours may be specified by the purchaser . When a truck mixer is used for the com- plete mixing of the concrete , the mixing operation shall be- gin within 30 minutes after the cement has ...
Page 349
... concrete Certification shall furnish to the purchaser , for each type of concrete and when any change in composition is made , a statement showing the quantities of materials used in making the con- crete . Sec . 15. ( a ) When strength ...
... concrete Certification shall furnish to the purchaser , for each type of concrete and when any change in composition is made , a statement showing the quantities of materials used in making the con- crete . Sec . 15. ( a ) When strength ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood