Uniform Building Code, Volume 3International Conference of Building Officials, 1952 - Building laws |
From inside the book
Results 1-3 of 52
Page 687
... containers with a water capacity of 300 lbs . or less . Underground : No requirement . Aboveground : Container . 8. With marking indicating the maximum level to which the container may be filled with liquid at temperatures be- tween 20 ...
... containers with a water capacity of 300 lbs . or less . Underground : No requirement . Aboveground : Container . 8. With marking indicating the maximum level to which the container may be filled with liquid at temperatures be- tween 20 ...
Page 708
... Containers may be stored in the open provided they are stored within a suitable enclosure where necessary to prevent tampering . Containers shall not be stored adjacent to a school , church , hospital , athletic field or other points of ...
... Containers may be stored in the open provided they are stored within a suitable enclosure where necessary to prevent tampering . Containers shall not be stored adjacent to a school , church , hospital , athletic field or other points of ...
Page 708
... containers , in storage . A warning , to keep open flames and fire away , shall be conspicuously posted . ( 1 ) Containers shall not be stored , whether full or empty , inside a store or place of business frequented by the public nor ...
... containers , in storage . A warning , to keep open flames and fire away , shall be conspicuously posted . ( 1 ) Containers shall not be stored , whether full or empty , inside a store or place of business frequented by the public nor ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood