Page 457
... Fire doors and fire dampers shall be arranged to close automatically and remain tightly closed , upon the operation of a fusible link or other approved heat actuated device located where readily affected by an abnormal rise of tem ...
... Fire doors and fire dampers shall be arranged to close automatically and remain tightly closed , upon the operation of a fusible link or other approved heat actuated device located where readily affected by an abnormal rise of tem ...
Page 566
... fire exposure period and , if required , during the hose stream test . When the test assembly com- prises two doors located one on each face of a common wall , the test conditions are met when the door on the unexposed side remains ...
... fire exposure period and , if required , during the hose stream test . When the test assembly com- prises two doors located one on each face of a common wall , the test conditions are met when the door on the unexposed side remains ...
Page 611
... Doors subject to damage from Rolling Steel falling materials at time of fire shall be mounted in reveal Fire Doors of wall so that no portion projects beyond the face of the ( Cont'd . ) wall . ( See Figures 34 , 35 and 36. ) Note : The ...
... Doors subject to damage from Rolling Steel falling materials at time of fire shall be mounted in reveal Fire Doors of wall so that no portion projects beyond the face of the ( Cont'd . ) wall . ( See Figures 34 , 35 and 36. ) Note : The ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood