Uniform Building Code, Volume 3International Conference of Building Officials, 1952 - Building laws |
From inside the book
Results 1-3 of 4
Page 676
... fusible plugs , or other parts of the system . 12.1.1 No stop valve shall be located between any auto- matic pressure - relief device or fusible plug and the part or parts of the system protected thereby , except when the parallel ...
... fusible plugs , or other parts of the system . 12.1.1 No stop valve shall be located between any auto- matic pressure - relief device or fusible plug and the part or parts of the system protected thereby , except when the parallel ...
Page 677
... fusible plug shall be determined as follows : Relief Devices in General ( Cont'd . ) or 3P d5 / 2 C = L ' / 2 d = C2L B 9P2 ( 2 ) where C minimum required discharge capacity in lbs . of air per min . d = internal diameter of pipe in in ...
... fusible plug shall be determined as follows : Relief Devices in General ( Cont'd . ) or 3P d5 / 2 C = L ' / 2 d = C2L B 9P2 ( 2 ) where C minimum required discharge capacity in lbs . of air per min . d = internal diameter of pipe in in ...
Page 700
... fusible plug ( not over 220 ° F. melting point ) which will cause the internal valve to close automatically in case of fire . ( g ) Not more than two plugged openings shall be permitted on a container of 1,200 gallons or less water ...
... fusible plug ( not over 220 ° F. melting point ) which will cause the internal valve to close automatically in case of fire . ( g ) Not more than two plugged openings shall be permitted on a container of 1,200 gallons or less water ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood