... hazard and ordinary hazard occupancies are given in succeeding paragraphs . The water supply needed for various occu- pancies including extra hazard occupancies must be de- termined by a study of the conditions obtaining in each case ...
... hazard and ordinary hazard occupancies are given in succeeding paragraphs . The water supply needed for various occu- pancies including extra hazard occupancies must be de- termined by a study of the conditions obtaining in each case ...
Page 528
... hazards which may be protected by carbon dioxide if the hazard is localized or enclosed . Attention is called , however , to the fact that carbon dioxide protection is especially adapted to extin- guishment of fires in flammable liquids ...
... hazards which may be protected by carbon dioxide if the hazard is localized or enclosed . Attention is called , however , to the fact that carbon dioxide protection is especially adapted to extin- guishment of fires in flammable liquids ...
Page 541
... hazards within this space by local , direct application of carbon dioxide . If the hazard protected by local , direct application is out of doors or only partly sheltered from natural winds , it is essential that the application of the ...
... hazards within this space by local , direct application of carbon dioxide . If the hazard protected by local , direct application is out of doors or only partly sheltered from natural winds , it is essential that the application of the ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood