Page 163
... ( Knot 5 is measured on wide face only . ) ( b ) Round or oval knots ( 4-6-7-8-9 ) on a narrow face shall be measured on the end section between lines parallel to the edges of the narrow face on which they occur . ( Knot 5 not measured on ...
... ( Knot 5 is measured on wide face only . ) ( b ) Round or oval knots ( 4-6-7-8-9 ) on a narrow face shall be measured on the end section between lines parallel to the edges of the narrow face on which they occur . ( Knot 5 not measured on ...
Page 211
... knot on a wide face is its average diam- eter , except knots that cross a corner of a pithless piece shall be measured only on the face containing the shorter portion of knot , and knots that extend entirely across the face shall be ...
... knot on a wide face is its average diam- eter , except knots that cross a corner of a pithless piece shall be measured only on the face containing the shorter portion of knot , and knots that extend entirely across the face shall be ...
Page 224
... knots measured on narrow faces , except knots that cross the corners of pithless pieces , are those which do not show on wide faces , and the size is the dis- ance between lines enclosing knot and parallel to edges of piece . ( b ) The ...
... knots measured on narrow faces , except knots that cross the corners of pithless pieces , are those which do not show on wide faces , and the size is the dis- ance between lines enclosing knot and parallel to edges of piece . ( b ) The ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood