Uniform Building Code, Volume 3International Conference of Building Officials, 1952 - Building laws |
From inside the book
Results 1-3 of 78
Page 163
... narrow face shall be measured on the end section between lines parallel to the edges of the narrow face on which they occur . ( Knot 5 not measured on narrow face . ) ( c ) Spiked knots ( 10-11-12-13 ) with the end section on one face ...
... narrow face shall be measured on the end section between lines parallel to the edges of the narrow face on which they occur . ( Knot 5 not measured on narrow face . ) ( c ) Spiked knots ( 10-11-12-13 ) with the end section on one face ...
Page 193
... Face On Narrow Face , or at Edge of Wide Face , Middle Third of Length ON NARROW FACE At Center Line of Wide Face Plank ( Cont'd . ) 234 | 1/2 3⁄4 1 4 6 8 10 12 14 16 AT EDGE OF WIDE FACE -----... 1 14 1/2 % 1 % 2 1 % 25 % 14 3 % 1 % 3 ...
... Face On Narrow Face , or at Edge of Wide Face , Middle Third of Length ON NARROW FACE At Center Line of Wide Face Plank ( Cont'd . ) 234 | 1/2 3⁄4 1 4 6 8 10 12 14 16 AT EDGE OF WIDE FACE -----... 1 14 1/2 % 1 % 2 1 % 25 % 14 3 % 1 % 3 ...
Page 233
... Face . Size of knot on a narrow face is taken Joist and as width between lines enclosing knot and parallel to edges Plank of piece . The only knots measured on narrow faces are those that do not show on wide faces . ( b ) Wide Face ...
... Face . Size of knot on a narrow face is taken Joist and as width between lines enclosing knot and parallel to edges Plank of piece . The only knots measured on narrow faces are those that do not show on wide faces . ( b ) Wide Face ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood