Uniform Building Code, Volume 3International Conference of Building Officials, 1952 - Building laws |
From inside the book
Results 1-3 of 87
Page 211
... permitted at the edge to the size permitted along the center line . ( d ) The sum of the sizes of all knots within the middle half of the length of any face , measured as specified by paragraphs 306 ( a ) and 306 ( b ) for the face ...
... permitted at the edge to the size permitted along the center line . ( d ) The sum of the sizes of all knots within the middle half of the length of any face , measured as specified by paragraphs 306 ( a ) and 306 ( b ) for the face ...
Page 224
... permitted in the middle third of length to twice that size at the ends of the piece , except that no knot shall exceed the size permitted along the center line of the wide face ; and the knots on wide faces may increase proportionately ...
... permitted in the middle third of length to twice that size at the ends of the piece , except that no knot shall exceed the size permitted along the center line of the wide face ; and the knots on wide faces may increase proportionately ...
Page 234
... permitted in middle third of length to twice that size at ends of piece , except that size of no knot shall exceed size permitted along center line of wide face . Size of knots on wide faces may increase propor- tionately from size ...
... permitted in middle third of length to twice that size at ends of piece , except that size of no knot shall exceed size permitted along center line of wide face . Size of knots on wide faces may increase propor- tionately from size ...
Other editions - View all
Common terms and phrases
aggregate allowable loads authority having jurisdiction average bars Beams and Stringers bending bolt BUILDING CODE STANDARD butt joints carbon dioxide cent center half center line checks compression compression members Compression Stress compressive strength concrete connector Cont'd diameter dimension distance door Douglas Fir Edge of Wide exceed Face inches feet fire fire doors flammable liquids Grade gypsum heartwood inch ½ incl installed joints Joist and Plank knots lag screw laminations less located lumber manufacturer material maximum measured metal minimum narrow face Nominal Width one-half inch one-quarter inch panel paragraph permitted piece pipe pith plates Posts and Timbers required not required shake shear side six inches sizes Slope of Grain spacing specified Splits sprinklers steel storage strength ratio stress Structural surface tank temperature tensile strength test specimen thickness tion UNIFORM BUILDING CODE valve wall Wane weight weld wide face Width of Face wood