Uniform Building Code, Volume 3International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 3
Page 67
... Aisles in which are installed seats , tables , merchandise , equipment or similar materials shall be provided with aisles leading to an exit . ( b ) Width . Every aisle shall be not less than three feet ( 3 ' ) wide if serving only one ...
... Aisles in which are installed seats , tables , merchandise , equipment or similar materials shall be provided with aisles leading to an exit . ( b ) Width . Every aisle shall be not less than three feet ( 3 ' ) wide if serving only one ...
Page 73
... aisle or exitway . 3. Stairs required . When an aisle is elevated more than eight inches ( 8 " ) above grade , the aisle shall be provided with a stairway or ramp whose width is not less than the width of the aisle . 4. Dead end . No ...
... aisle or exitway . 3. Stairs required . When an aisle is elevated more than eight inches ( 8 " ) above grade , the aisle shall be provided with a stairway or ramp whose width is not less than the width of the aisle . 4. Dead end . No ...
Page 74
... aisle when the guardrail is parallel and ad- jacent to the aisle . EXCEPTION : The height may be reduced to thirty - six inches ( 36 ′′ ) for guardrails located in front of the grand- stand . A midrail shall be placed adjacent to any ...
... aisle when the guardrail is parallel and ad- jacent to the aisle . EXCEPTION : The height may be reduced to thirty - six inches ( 36 ′′ ) for guardrails located in front of the grand- stand . A midrail shall be placed adjacent to any ...
Contents
CHAPTER 1TITLE and Scope | 7 |
CHAPTER 6Structural Requirements | 15 |
APPENDIX | 21 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
20 feet accordance additional aisle appliances applicable approved balcony basement Building Official building or portion building or structure ceiling cellar cent Chapter chimney concrete conform connected construction Continued corridors court defined Definitions designed determined distance doors Edition enclosed enclosures equipped exceed EXCEPTION existing exit exit door extend exterior walls fire fire-resistive fireplace five floor four glass grade ground Group guest height horizontal hour less inches incombustible inspection installed interior least less than 20 living located maintained materials means metal occupant load passageway permitted permitted less persons placed plans portion portion thereof pressure protected ramp repair resistance roof seats separate serving side space specified square feet stairs stairway stand standpipes story supports surface Table thickness tion Type Uniform Building Code vertical Volume width wood