Uniform Building Code, Volume 3International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 39
Page 25
... APPROVED . " Such approved plans and specifications shall not be changed , modified , or altered without authoriza- tion from the Building Official , and all work shall be done in accordance with the approved plans . The Building ...
... APPROVED . " Such approved plans and specifications shall not be changed , modified , or altered without authoriza- tion from the Building Official , and all work shall be done in accordance with the approved plans . The Building ...
Page 31
... APPROVED as to materials and types of construction , refers to approval by the Building Official as the result of ... APPROVED AGENCY is an established and recognized agency regularly engaged in conducting tests or furnishing inspection ...
... APPROVED as to materials and types of construction , refers to approval by the Building Official as the result of ... APPROVED AGENCY is an established and recognized agency regularly engaged in conducting tests or furnishing inspection ...
Page 51
... approved preservative , all marked or branded by an approved agency , shall be nearer than six inches ( 6 " ) to any earth . See Subsection 2517 ( c ) for plates and sills . EXCEPTION : Any species of untreated wood may be used in ...
... approved preservative , all marked or branded by an approved agency , shall be nearer than six inches ( 6 " ) to any earth . See Subsection 2517 ( c ) for plates and sills . EXCEPTION : Any species of untreated wood may be used in ...
Contents
CHAPTER 1TITLE and Scope | 7 |
CHAPTER 6Structural Requirements | 15 |
APPENDIX | 21 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
20 feet accordance additional aisle appliances applicable approved balcony basement Building Official building or portion building or structure ceiling cellar cent Chapter chimney concrete conform connected construction Continued corridors court defined Definitions designed determined distance doors Edition enclosed enclosures equipped exceed EXCEPTION existing exit exit door extend exterior walls fire fire-resistive fireplace five floor four glass grade ground Group guest height horizontal hour less inches incombustible inspection installed interior least less than 20 living located maintained materials means metal occupant load passageway permitted permitted less persons placed plans portion portion thereof pressure protected ramp repair resistance roof seats separate serving side space specified square feet stairs stairway stand standpipes story supports surface Table thickness tion Type Uniform Building Code vertical Volume width wood