Uniform Building Code, Volume 3International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 19
Page 44
... CONSTRUCTION CHAPTER 17 - CLASSIFICATION OF ALL BUILDINGS BY TYPES OF ... fire . Every building shall be classified by the Building Official into one ... resistive protection are required , such requirements shall be the minimum ...
... CONSTRUCTION CHAPTER 17 - CLASSIFICATION OF ALL BUILDINGS BY TYPES OF ... fire . Every building shall be classified by the Building Official into one ... resistive protection are required , such requirements shall be the minimum ...
Page 49
International Conference of Building Officials. EXCEPTIONS : 1. For Type III construction , provided Cornices such projections ... construction in Fire Zone No. 1 ; of combustible one- hour fire - resistive construction or heavy - timber ...
International Conference of Building Officials. EXCEPTIONS : 1. For Type III construction , provided Cornices such projections ... construction in Fire Zone No. 1 ; of combustible one- hour fire - resistive construction or heavy - timber ...
Page 65
International Conference of Building Officials. more than four stories in height and shall be of not less than Exit Enclosures one - hour fire - resistive construction elsewhere . ( c ) Openings into Enclosures . There shall be no ...
International Conference of Building Officials. more than four stories in height and shall be of not less than Exit Enclosures one - hour fire - resistive construction elsewhere . ( c ) Openings into Enclosures . There shall be no ...
Contents
CHAPTER 1TITLE and Scope | 7 |
CHAPTER 6Structural Requirements | 15 |
APPENDIX | 21 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
20 feet aisle annealed glass appliances approved Building Official building or portion building or structure ceiling Chapter combustible Continued corbeled corridors dry standpipes dwelling unit eighteen inches 18 enclosed equipped exceed exit court exit door exit passageway exits required exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less Fire Zone fire-resistive rating fireplace Firestopping glass glazed grade Group guardrail guest room habitable room handrails horizontal exit hour elsewhere hour less incombustible inspection installed less than 20 located locking device Masonry chimneys materials mechanical ventilation minimum occu occupant load one-hour fire-resistive panic hardware permitted less portion thereof ramp repair required exit required width roof smokeproof enclosure soffits space specified in Section square feet stairs stories in height Subsection superficial floor area thickness thirty inches 30 tion twelve inches 12 types of construction U.B.C. Standard Uniform Building Code Ventilation vertical water closet