Page 51
... minimum total area of ventilating openings shall be proportioned on the basis of two square feet ( 2 sq . ft . ) for ... Minimum clearance between bottom of floor joist or bot- tom of floors without joists and the ground beneath shall be ...
... minimum total area of ventilating openings shall be proportioned on the basis of two square feet ( 2 sq . ft . ) for ... Minimum clearance between bottom of floor joist or bot- tom of floors without joists and the ground beneath shall be ...
Page 79
... MINIMUM PASSAGEWAY AREAS FOR TYPE OF MASONRY CHIMNEY MASONRY CHIMNEYS ' MINIMUM CROSS - SECTIONAL AREA Square or Rectangle 1/10 of opening Minimum Lined with Firebrick or Unlined 85 Sq . in . 1/8 of opening Minimum 100 Sq . in . Round ...
... MINIMUM PASSAGEWAY AREAS FOR TYPE OF MASONRY CHIMNEY MASONRY CHIMNEYS ' MINIMUM CROSS - SECTIONAL AREA Square or Rectangle 1/10 of opening Minimum Lined with Firebrick or Unlined 85 Sq . in . 1/8 of opening Minimum 100 Sq . in . Round ...
Page 89
... Minimum Frame Lap ...... 4 " Minimum Glass Edge Clearance Continuous Glazing Rab- bet and Glass Retainer3 .. 30 45 95 Resilient Setting Material1 .. 40 24 10 GLASS AREA 98 81 70 61 55 50 UP TO 6 SQ . FT . 6 TO 14 14 TO 32 32 TO 50 SQ ...
... Minimum Frame Lap ...... 4 " Minimum Glass Edge Clearance Continuous Glazing Rab- bet and Glass Retainer3 .. 30 45 95 Resilient Setting Material1 .. 40 24 10 GLASS AREA 98 81 70 61 55 50 UP TO 6 SQ . FT . 6 TO 14 14 TO 32 32 TO 50 SQ ...
Contents
CHAPTER 1TITLE and Scope | 7 |
CHAPTER 6Structural Requirements | 15 |
APPENDIX | 21 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
20 feet accordance additional aisle appliances applicable approved balcony basement Building Official building or portion building or structure ceiling cellar cent Chapter chimney concrete conform connected construction Continued corridors court defined Definitions designed determined distance doors Edition enclosed enclosures equipped exceed EXCEPTION existing exit exit door extend exterior walls fire fire-resistive fireplace five floor four glass grade ground Group guest height horizontal hour less inches incombustible inspection installed interior least less than 20 living located maintained materials means metal occupant load passageway permitted permitted less persons placed plans portion portion thereof pressure protected ramp repair resistance roof seats separate serving side space specified square feet stairs stairway stand standpipes story supports surface Table thickness tion Type Uniform Building Code vertical Volume width wood