Uniform Building Code, Volume 3International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 33
Page 44
... specified in this Code , may be used . Portions of buildings separated as specified in Section 505 ( c ) may be considered a separate building for classification of types of construction . When there is no such separation , the area of ...
... specified in this Code , may be used . Portions of buildings separated as specified in Section 505 ( c ) may be considered a separate building for classification of types of construction . When there is no such separation , the area of ...
Page 59
... specified in Section 4306 ( g ) . EXCEPTION : In corridors of Groups F and G Occu- pancies , interior openings may have fixed plain glass as specified in Section 5406 of unlimited area provided the corridors are at least ten feet ( 10 ...
... specified in Section 4306 ( g ) . EXCEPTION : In corridors of Groups F and G Occu- pancies , interior openings may have fixed plain glass as specified in Section 5406 of unlimited area provided the corridors are at least ten feet ( 10 ...
Page 67
... specified in this Subsection . In interior stairways the floor level leading direct to the exterior shall be clearly indicated . Group A Occupancies and Groups B , D and H Occupancies with an occupant load of more than 50 . All other ...
... specified in this Subsection . In interior stairways the floor level leading direct to the exterior shall be clearly indicated . Group A Occupancies and Groups B , D and H Occupancies with an occupant load of more than 50 . All other ...
Contents
SEC H101 | 7 |
CHAPTER 6Structural Requirements | 15 |
SEC 504 | 29 |
Copyright | |
4 other sections not shown
Other editions - View all
Common terms and phrases
20 feet aisle annealed glass appliances approved Building Official building or portion building or structure ceiling Chapter combustible Continued corbeled corridors dry standpipes dwelling unit eighteen inches 18 enclosed equipped exceed exit court exit door exit passageway exits required exterior exit balcony exterior walls feet 1 hour feet Not permitted feet Protected less Fire Zone fire-resistive rating fireplace Firestopping glass glazed grade Group guardrail guest room habitable room handrails horizontal exit hour elsewhere hour less incombustible inspection installed less than 20 located locking device Masonry chimneys materials mechanical ventilation minimum occu occupant load one-hour fire-resistive panic hardware permitted less portion thereof ramp repair required exit required width roof smokeproof enclosure soffits space specified in Section square feet stairs stories in height Subsection superficial floor area thickness thirty inches 30 tion twelve inches 12 types of construction U.B.C. Standard Uniform Building Code Ventilation vertical water closet