International Conference of Building Officials. Definitions ( Continued ) BUILDING OFFICIAL . Building ... floor to the finished ceiling . CELLAR . Cellar is that portion of a ... superficial floor area in a dormi- tory is a guest room .
International Conference of Building Officials. Definitions ( Continued ) BUILDING OFFICIAL . Building ... floor to the finished ceiling . CELLAR . Cellar is that portion of a ... superficial floor area in a dormi- tory is a guest room .
Page 12
... BUILDING . ( See Chapter 10 , page 16. ) SUPERFICIAL FLOOR AREA . Superficial floor area shall mean the net floor area within the enclosing walls of the room in which the ceiling height is not less than five feet ( 5 ′ ) , excluding ...
... BUILDING . ( See Chapter 10 , page 16. ) SUPERFICIAL FLOOR AREA . Superficial floor area shall mean the net floor area within the enclosing walls of the room in which the ceiling height is not less than five feet ( 5 ′ ) , excluding ...
Page 13
... superficial floor area . Every room used for sleeping purposes shall have not less than ninety square feet ( 90 sq . ft . ) of superficial floor area . Where more than two persons occupy a room used for sleeping purposes the required ...
... superficial floor area . Every room used for sleeping purposes shall have not less than ninety square feet ( 90 sq . ft . ) of superficial floor area . Where more than two persons occupy a room used for sleeping purposes the required ...
Contents
CHAPTER 1TITLE and Scope | 7 |
CHAPTER 6Structural Requirements | 15 |
APPENDIX | 21 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
20 feet accordance additional aisle appliances applicable approved balcony basement Building Official building or portion building or structure ceiling cellar cent Chapter chimney concrete conform connected construction Continued corridors court defined Definitions designed determined distance doors Edition enclosed enclosures equipped exceed EXCEPTION existing exit exit door extend exterior walls fire fire-resistive fireplace five floor four glass grade ground Group guest height horizontal hour less inches incombustible inspection installed interior least less than 20 living located maintained materials means metal occupant load passageway permitted permitted less persons placed plans portion portion thereof pressure protected ramp repair resistance roof seats separate serving side space specified square feet stairs stairway stand standpipes story supports surface Table thickness tion Type Uniform Building Code vertical Volume width wood