Uniform Building Code, Volume 2International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 9
Page 2-34
... ducts , if all the following conditions are satisfied : 12.1 Lateral motion of the raceway will not cause damaging impact with other systems . 12.2 Lateral motion of the raceway does not cause loss of system vertical support . 12.3 Rod ...
... ducts , if all the following conditions are satisfied : 12.1 Lateral motion of the raceway will not cause damaging impact with other systems . 12.2 Lateral motion of the raceway does not cause loss of system vertical support . 12.3 Rod ...
Page 2-107
... ducts shall be accurately placed and adequately supported before concrete is placed , and shall be secured against displacement within toler- ances of this section . 1907.5.2 Unless otherwise approved by the building official , re ...
... ducts shall be accurately placed and adequately supported before concrete is placed , and shall be secured against displacement within toler- ances of this section . 1907.5.2 Unless otherwise approved by the building official , re ...
Page 2-151
... Ducts . 1918.15.1 Ducts for grouted or unbonded tendons shall be mortar - tight and nonreactive with concrete , tendons or filler mate- rials . 1918.15.2 Ducts for grouted single wire , strand or bar tendons shall have an inside ...
... Ducts . 1918.15.1 Ducts for grouted or unbonded tendons shall be mortar - tight and nonreactive with concrete , tendons or filler mate- rials . 1918.15.2 Ducts for grouted single wire , strand or bar tendons shall have an inside ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 2-4 |
153 | 2-28 |
UBC Standard 72 Fire Tests of Door Assemblies | 2-43 |
Copyright | |
13 other sections not shown
Other editions - View all
Common terms and phrases
1997 UNIFORM BUILDING accordance with Section allowable stress Allowable Stress Design analysis anchor applied ASTM axial load bars beam bending bolts building official calculated column compression members compressive strength computed concrete connections construction dead load deflection deformed design strength Design Value determined diameter diaphragm displacement distance earthquake edge effects elements exceed factored feet flange flexural members floor foot Formula grout horizontal joints joists kN/m² lateral forces less live load load combinations longitudinal lumber masonry maximum ment minimum modulus of elasticity nominal nonbuilding structures nonprestressed panel permitted plate plywood pounds per square precast ratio requirements of Section roof seismic forces Seismic Zones Select Structural shear reinforcement shear strength shear stress shear walls shotcrete slab soil spacing span specified in Section square inch MPa steel story studs Table tensile thickness tion torsion UBC Standard UNIFORM BUILDING CODE vertical welded width wire wood yield strength