Uniform Building Code, Volume 2International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 80
Page 2-114
... axial load 0.90 1909.3.2.2 Axial load and axial load with flexure . ( For axial load with flexure , both axial load and moment nominal strength shall be multiplied by appropriate single value of 4. ) 0.90 Axial tension and axial tension ...
... axial load 0.90 1909.3.2.2 Axial load and axial load with flexure . ( For axial load with flexure , both axial load and moment nominal strength shall be multiplied by appropriate single value of 4. ) 0.90 Axial tension and axial tension ...
Page 2-117
... axial loads or to combined flex- ure and axial loads . 1910.2 Design Assumptions . 1910.2.1 Strength design of members for flexure and axial loads shall be based on assumptions given in the following items and on satisfaction of ...
... axial loads or to combined flex- ure and axial loads . 1910.2 Design Assumptions . 1910.2.1 Strength design of members for flexure and axial loads shall be based on assumptions given in the following items and on satisfaction of ...
Page 2-219
... axial load , the value of shall be determined from Formula ( 8-1 ) : Φ P 0 = 0.8 - Arf'm and 0.60 ≤ ≤ 0.80 ( 8-1 ) 2108.1.4.4.2 Shear . Shear : $ = 0.80 . 2108.1.4.5 Anchor . Anchor bolts : $ = 0.80 . 2108.1.4.6 Reinforcement . 2108.1 ...
... axial load , the value of shall be determined from Formula ( 8-1 ) : Φ P 0 = 0.8 - Arf'm and 0.60 ≤ ≤ 0.80 ( 8-1 ) 2108.1.4.4.2 Shear . Shear : $ = 0.80 . 2108.1.4.5 Anchor . Anchor bolts : $ = 0.80 . 2108.1.4.6 Reinforcement . 2108.1 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 22 |
Review the building for conformity with the occupancy requirements in Sections 303 through 312 | 2-10 |
Review the building for conformity with structural engineering regulations and requirements for materials of construction See Chap | 2-23 |
Copyright | |
14 other sections not shown
Other editions - View all
Common terms and phrases
1997 UNIFORM BUILDING accordance with Section allowable stress Allowable Stress Design anchor applied ASTM axial load bars beam bending bolts braced building official calculated column compression members compressive strength compressive stress computed concrete conform connections construction dead load deflection design strength determined diameter diaphragm distance edge effective elements exceed factored flange flexural members foot Formula frame grout horizontal joints joists kN/m² less live load load combinations longitudinal lumber masonry materials maximum ment minimum mm² modulus of elasticity nominal nonbuilding structures nonprestressed panel permitted piles plate plywood pounds per square precast ratio requirements of Section resist roof seismic forces Seismic Zones Select Structural shear reinforcement shear strength shear stress shear walls shotcrete slab soil spacing span specified in Section square inch MPa steel studs Table tensile thickness tion torsion UBC Standard UNIFORM BUILDING CODE vertical welded width wire wood yield strength