Page 16
... Chimneys Smokestacks 3703. Gas Vents 3704 . Patent Chimneys 3705. Smoke Pipes and Thimbles Fireplaces Warm Air Furnaces 3706 . 3707 . 3708 . 3709 . Low Pressure Steam Heating Plants Boilers 3710 . Stoves 3711. Gas Ranges , Domestic ...
... Chimneys Smokestacks 3703. Gas Vents 3704 . Patent Chimneys 3705. Smoke Pipes and Thimbles Fireplaces Warm Air Furnaces 3706 . 3707 . 3708 . 3709 . Low Pressure Steam Heating Plants Boilers 3710 . Stoves 3711. Gas Ranges , Domestic ...
Page 234
... chimneys specified in Section 3701 , in which case the thickness of the metal shall be not less than one - fourth inch ( 14 " ) . Such stacks when used for manufacturing , for high pressure boilers , furnaces or other similar heating or ...
... chimneys specified in Section 3701 , in which case the thickness of the metal shall be not less than one - fourth inch ( 14 " ) . Such stacks when used for manufacturing , for high pressure boilers , furnaces or other similar heating or ...
Page 323
... Chimneys and heating apparatus Construction Defined Doors .. Enclosure of vertical openings Exit facilities .. Exit lights ..... Fire extinguishing apparatus . Flammable liquids prohibited Light and ventilation 702 704 708 702 701 .703 ...
... Chimneys and heating apparatus Construction Defined Doors .. Enclosure of vertical openings Exit facilities .. Exit lights ..... Fire extinguishing apparatus . Flammable liquids prohibited Light and ventilation 702 704 708 702 701 .703 ...
Contents
Part IAdministrative | 19 |
Enforcement | 26 |
Part IIIRequirements Based on Occupancy | 36 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation adjacent property lines approved balconies bars beams brick Building Inspector building or structure ceiling cent Chapter 33 coat Code columns compression construction as specified doors dry standpipes E occupancies Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flammable liquids floor area foot frame girders grade Group A occupancies Group H gypsum H occupancies horizontal joists less than one-hour lime live load masonry metal lath mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit portland cement pounds per square proscenium protected ramps reinforced concrete rivets roof covering roofing felt seating capacity Section 503 shear six inches slab smokeproof towers space specified in Chapter specified in Section square feet square inch stairs stairways standpipes storage structural steel stucco studs supported tests thereof thickness tion Type V buildings TYPES OF CONSTRUCTION ventilation vertical openings width wire wood