Uniform Building CodePacific Coast Building Officials Conference, 1939 - Building laws |
From inside the book
Results 1-3 of 70
Page 224
... doors providing egress from public hallways and all doors providing egress from the building shall open in the direction of exit travel , except sliding doors as provided in Section 3304 . Sec . 3304. Doors shall not open immediately on ...
... doors providing egress from public hallways and all doors providing egress from the building shall open in the direction of exit travel , except sliding doors as provided in Section 3304 . Sec . 3304. Doors shall not open immediately on ...
Page 265
... doors made of two plies of wood one inch ( 1 " ) nominal in thickness and covered with sheet metal , the door to be constructed in accordance with the " Underwriters ' Standard for Tin - Clad Fire Doors and Shutters , " Edition of July ...
... doors made of two plies of wood one inch ( 1 " ) nominal in thickness and covered with sheet metal , the door to be constructed in accordance with the " Underwriters ' Standard for Tin - Clad Fire Doors and Shutters , " Edition of July ...
Page 266
... door . Locks . Doors shall be provided with a mortise or unit lock which has a latch bolt with a throw of not less than three - fourths inch ( 4 " ) . When mounted in pairs the normally standing door shall have a push bolt at the top ...
... door . Locks . Doors shall be provided with a mortise or unit lock which has a latch bolt with a throw of not less than three - fourths inch ( 4 " ) . When mounted in pairs the normally standing door shall have a push bolt at the top ...
Contents
Part IAdministrative | 19 |
Enforcement | 26 |
Part IIIRequirements Based on Occupancy | 36 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation adjacent property lines approved balconies bars beams brick Building Inspector building or structure ceiling cent Chapter 33 coat Code columns compression construction as specified doors dry standpipes E occupancies Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flammable liquids floor area foot frame girders grade Group A occupancies Group H gypsum H occupancies horizontal joists less than one-hour lime live load masonry metal lath mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit portland cement pounds per square proscenium protected ramps reinforced concrete rivets roof covering roofing felt seating capacity Section 503 shear six inches slab smokeproof towers space specified in Chapter specified in Section square feet square inch stairs stairways standpipes storage structural steel stucco studs supported tests thereof thickness tion Type V buildings TYPES OF CONSTRUCTION ventilation vertical openings width wire wood