Uniform Building CodePacific Coast Building Officials Conference, 1939 - Building laws |
From inside the book
Results 1-3 of 37
Page 119
... Gypsum as used in this section means a product Gypsum containing not less than 64-2 per cent by weight of calcium sulphate combined with water . Neat gypsum , gypsum fiber concrete , or gypsum coarse aggregate concrete used in floor and ...
... Gypsum as used in this section means a product Gypsum containing not less than 64-2 per cent by weight of calcium sulphate combined with water . Neat gypsum , gypsum fiber concrete , or gypsum coarse aggregate concrete used in floor and ...
Page 258
... gypsum blocks 3 pl . 3 22 Poured gypsum 2 12 1 221 Metal lath and gypsum or 22 1 Portland cement plaster Grade A concrete 2 12 1 1 Grade B concrete 3 212 12 1 Gunite 2 12 1 34 Brick of clay , shale , con- crete or sand - lime 34 24 24 ...
... gypsum blocks 3 pl . 3 22 Poured gypsum 2 12 1 221 Metal lath and gypsum or 22 1 Portland cement plaster Grade A concrete 2 12 1 1 Grade B concrete 3 212 12 1 Gunite 2 12 1 34 Brick of clay , shale , con- crete or sand - lime 34 24 24 ...
Page 299
... gypsum plaster mixed with not more than two parts of sand . This may be applied over a brown mortar base while it is still green . Sec . 4718. Interior hardwall or gypsum plaster over metal Hardwall lath must be at least three - coat ...
... gypsum plaster mixed with not more than two parts of sand . This may be applied over a brown mortar base while it is still green . Sec . 4718. Interior hardwall or gypsum plaster over metal Hardwall lath must be at least three - coat ...
Contents
Part IAdministrative | 19 |
Enforcement | 26 |
Part IIIRequirements Based on Occupancy | 36 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation adjacent property lines approved balconies bars beams brick Building Inspector building or structure ceiling cent Chapter 33 coat Code columns compression construction as specified doors dry standpipes E occupancies Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flammable liquids floor area foot frame girders grade Group A occupancies Group H gypsum H occupancies horizontal joists less than one-hour lime live load masonry metal lath mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit portland cement pounds per square proscenium protected ramps reinforced concrete rivets roof covering roofing felt seating capacity Section 503 shear six inches slab smokeproof towers space specified in Chapter specified in Section square feet square inch stairs stairways standpipes storage structural steel stucco studs supported tests thereof thickness tion Type V buildings TYPES OF CONSTRUCTION ventilation vertical openings width wire wood