... iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fire - protection of steel , iron , or wood structural members may be omitted unless otherwise provided , because of location as in Part IV or ...
... iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fire - protection of steel , iron , or wood structural members may be omitted unless otherwise provided , because of location as in Part IV or ...
Page 151
... iron or steel not thinner than standard wrought - iron pipe , have a nominal inside diameter not over two inches , and are spaced not less than three diameters on centers . Embedded pipes or conduits other than those merely passing ...
... iron or steel not thinner than standard wrought - iron pipe , have a nominal inside diameter not over two inches , and are spaced not less than three diameters on centers . Embedded pipes or conduits other than those merely passing ...
Page 183
... IRON ( Quality and Design ) Sec . 2701. The quality and design of all structural steel and Quality iron used in buildings or structures shall conform to the require- and ments specified in this Chapter . Design Structural steel shall be ...
... IRON ( Quality and Design ) Sec . 2701. The quality and design of all structural steel and Quality iron used in buildings or structures shall conform to the require- and ments specified in this Chapter . Design Structural steel shall be ...
Contents
Part IAdministrative | 19 |
Enforcement | 26 |
Part IIIRequirements Based on Occupancy | 36 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation adjacent property lines approved balconies bars beams brick Building Inspector building or structure ceiling cent Chapter 33 coat Code columns compression construction as specified doors dry standpipes E occupancies Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flammable liquids floor area foot frame girders grade Group A occupancies Group H gypsum H occupancies horizontal joists less than one-hour lime live load masonry metal lath mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit portland cement pounds per square proscenium protected ramps reinforced concrete rivets roof covering roofing felt seating capacity Section 503 shear six inches slab smokeproof towers space specified in Chapter specified in Section square feet square inch stairs stairways standpipes storage structural steel stucco studs supported tests thereof thickness tion Type V buildings TYPES OF CONSTRUCTION ventilation vertical openings width wire wood