Uniform Building CodePacific Coast Building Officials Conference, 1939 - Building laws |
From inside the book
Results 1-3 of 80
Page 92
... less than two inches ( 2 " ) thick and not less in width than the wall framing supported thereon , and of the quality specified in Section 2204 shall be placed under all wood frame walls or partitions directly supported by masonry or ...
... less than two inches ( 2 " ) thick and not less in width than the wall framing supported thereon , and of the quality specified in Section 2204 shall be placed under all wood frame walls or partitions directly supported by masonry or ...
Page 93
... less in width and not less than three such nails when such sheathing boards exceed eight inches ( 8 " ) in width . In all cases , except where the building is not intended for human occupancy , or where the interior face of the studs is ...
... less in width and not less than three such nails when such sheathing boards exceed eight inches ( 8 " ) in width . In all cases , except where the building is not intended for human occupancy , or where the interior face of the studs is ...
Page 214
... less than eight inches ( 8 " ) thick and those of hollow clay tile , concrete block or tile or hollow walls of brick shall be not less in thickness than one - eighteenth of the height between floors or floor beams but never less than ...
... less than eight inches ( 8 " ) thick and those of hollow clay tile , concrete block or tile or hollow walls of brick shall be not less in thickness than one - eighteenth of the height between floors or floor beams but never less than ...
Contents
Part IAdministrative | 19 |
Enforcement | 26 |
Part IIIRequirements Based on Occupancy | 36 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation adjacent property lines approved balconies bars beams brick Building Inspector building or structure ceiling cent Chapter 33 coat Code columns compression construction as specified doors dry standpipes E occupancies Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flammable liquids floor area foot frame girders grade Group A occupancies Group H gypsum H occupancies horizontal joists less than one-hour lime live load masonry metal lath mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit portland cement pounds per square proscenium protected ramps reinforced concrete rivets roof covering roofing felt seating capacity Section 503 shear six inches slab smokeproof towers space specified in Chapter specified in Section square feet square inch stairs stairways standpipes storage structural steel stucco studs supported tests thereof thickness tion Type V buildings TYPES OF CONSTRUCTION ventilation vertical openings width wire wood