Page 121
... Reinforced Brick Masonry Type of Stress 1C - 2L - 42S 1C - 42S Mortar Cement Grout Pounds per sq . in . Compression ... Reinforced Brick Masonry . The formulas and assump- tions used in the design of reinforced brick masonry shall be the ...
... Reinforced Brick Masonry Type of Stress 1C - 2L - 42S 1C - 42S Mortar Cement Grout Pounds per sq . in . Compression ... Reinforced Brick Masonry . The formulas and assump- tions used in the design of reinforced brick masonry shall be the ...
Page 142
... REINFORCED CONCRETE ( Quality and Design ) Sec . 2601. The quality of the materials used in reinforced concrete and the quality of reinforced concrete shall conform to the physical and chemical properties as specified in Sections 2604 ...
... REINFORCED CONCRETE ( Quality and Design ) Sec . 2601. The quality of the materials used in reinforced concrete and the quality of reinforced concrete shall conform to the physical and chemical properties as specified in Sections 2604 ...
Page 210
... reinforced concrete shall be not less than six inches ( 6 " ) in thickness for the uppermost fifteen feet ( 15 ' ) of their height ; and for each successive twenty - five feet ( 25 ' ) or fraction thereof downward , the minimum ...
... reinforced concrete shall be not less than six inches ( 6 " ) in thickness for the uppermost fifteen feet ( 15 ' ) of their height ; and for each successive twenty - five feet ( 25 ' ) or fraction thereof downward , the minimum ...
Contents
Part IAdministrative | 19 |
Enforcement | 26 |
Part IIIRequirements Based on Occupancy | 36 |
Copyright | |
44 other sections not shown
Other editions - View all
Common terms and phrases
A. S. T. M. Designation adjacent property lines approved balconies bars beams brick Building Inspector building or structure ceiling cent Chapter 33 coat Code columns compression construction as specified doors dry standpipes E occupancies Enclosure of Vertical exceed exit exterior walls Fire Zone fire-protected flammable liquids floor area foot frame girders grade Group A occupancies Group H gypsum H occupancies horizontal joists less than one-hour lime live load masonry metal lath mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit portland cement pounds per square proscenium protected ramps reinforced concrete rivets roof covering roofing felt seating capacity Section 503 shear six inches slab smokeproof towers space specified in Chapter specified in Section square feet square inch stairs stairways standpipes storage structural steel stucco studs supported tests thereof thickness tion Type V buildings TYPES OF CONSTRUCTION ventilation vertical openings width wire wood