Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 4
Page 4
... WALL FRAMING MASONRY SOLID MASONRY - GROUTED MASONRY REINFORCED GROUTED MASONRY HOLLOW UNIT MASONRY CAVITY WALL MASONRY STONE MASONRY VENEERED WALLS DOORS AND STAIRWAYS PLASTERING AND INSTALLATION OF WALLBOARD LATHING PLASTERING ...
... WALL FRAMING MASONRY SOLID MASONRY - GROUTED MASONRY REINFORCED GROUTED MASONRY HOLLOW UNIT MASONRY CAVITY WALL MASONRY STONE MASONRY VENEERED WALLS DOORS AND STAIRWAYS PLASTERING AND INSTALLATION OF WALLBOARD LATHING PLASTERING ...
Page 27
... cavity walls . Unit ties shall be of sufficient length to engage all wythes , with ends embedded not less than one ... wall when used to support structural mem- bers and not more than six inches ( 6 " ) when used to support a chimney built ...
... cavity walls . Unit ties shall be of sufficient length to engage all wythes , with ends embedded not less than one ... wall when used to support structural mem- bers and not more than six inches ( 6 " ) when used to support a chimney built ...
Page 29
... cavity walls . There shall be one metal tie for not more than each four and one - half square feet ( 41⁄2 sq . ft . ) of wall area . Ties in alternate courses shall be staggered , and the maximum vertical distance between ties shall not ...
... cavity walls . There shall be one metal tie for not more than each four and one - half square feet ( 41⁄2 sq . ft . ) of wall area . Ties in alternate courses shall be staggered , and the maximum vertical distance between ties shall not ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP II GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles