Page 14
... Joists or rafters of other grades , other woods , and other sizes may be used , in which case they shall not be stressed to exceed the maximum allowable fiber stress as specified in Chapter 25 of the Uniform Building Code , Volume I ...
... Joists or rafters of other grades , other woods , and other sizes may be used , in which case they shall not be stressed to exceed the maximum allowable fiber stress as specified in Chapter 25 of the Uniform Building Code , Volume I ...
Page 17
... JOISTS USING NONSTRESS - GRADED LUMBER ' MAXIMUM ALLOWABLE SPAN ( Feet and Inches ) Ceiling Ceiling Joists Joists ( Inches ) ( Inches ) GROUP I GROUP II GROUP III GROUP IV2 12 11-6 11-0 9-6 5-6 2 x 4 16 10-6 10-0 8-6 5-0 12 18-0 16-6 15 ...
... JOISTS USING NONSTRESS - GRADED LUMBER ' MAXIMUM ALLOWABLE SPAN ( Feet and Inches ) Ceiling Ceiling Joists Joists ( Inches ) ( Inches ) GROUP I GROUP II GROUP III GROUP IV2 12 11-6 11-0 9-6 5-6 2 x 4 16 10-6 10-0 8-6 5-0 12 18-0 16-6 15 ...
Page 53
... JOISTS SOLID BLOCKING OVER GIRDER DOUBLE JOISTS UNDER BEARING PARTITIONS . IF JOISTS ARE 1 " x3 " CROSS BRIDGING FOR JOIST SPANS OF MORE THAN 8 ' - 0 " SEPARATED FOR PIPES , BLOCK 4 ' - 0 " O.C . MAX . OFF FLOOR CONSTRUCTION CLEARANCE ...
... JOISTS SOLID BLOCKING OVER GIRDER DOUBLE JOISTS UNDER BEARING PARTITIONS . IF JOISTS ARE 1 " x3 " CROSS BRIDGING FOR JOIST SPANS OF MORE THAN 8 ' - 0 " SEPARATED FOR PIPES , BLOCK 4 ' - 0 " O.C . MAX . OFF FLOOR CONSTRUCTION CLEARANCE ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles