Page 11
... Lintel Masonry over the fireplace opening shall be supported by an incombustible lintel . [ Sec . 3704 ( i ) . ] Hearth Every fireplace shall be provided with an approved incom- bustible hearth slab at least twelve inches ( 12 " ) wider ...
... Lintel Masonry over the fireplace opening shall be supported by an incombustible lintel . [ Sec . 3704 ( i ) . ] Hearth Every fireplace shall be provided with an approved incom- bustible hearth slab at least twelve inches ( 12 " ) wider ...
Page 50
... LINTEL 2/8 " AT 12 " INCOMBUSTIBLE LINTEL HEIGHT 3/8 " AT.12 " 3/8 " AT HEIGHT 10 " 18 4- REMOVE -GRADE UNLINED CHIMNEY SECTION DETAIL 1 20 4 " REMOVE 18 " GRADE 12 " LINED CHIMNEY SECTION DETAIL 2 10 " UNLINED 8 " IF LINED WITH ...
... LINTEL 2/8 " AT 12 " INCOMBUSTIBLE LINTEL HEIGHT 3/8 " AT.12 " 3/8 " AT HEIGHT 10 " 18 4- REMOVE -GRADE UNLINED CHIMNEY SECTION DETAIL 1 20 4 " REMOVE 18 " GRADE 12 " LINED CHIMNEY SECTION DETAIL 2 10 " UNLINED 8 " IF LINED WITH ...
Page 55
... LINTELS - 2-1 / 2 " BARS , EXTEND 20 " BEYOND EDGE OF OPENING . MAX . SPAN 6 ' - 0 " STEEL LINTEL , ALTERNATE 20-0 " MAX . 18 " MIN . 9-0 " FOR 6 " WALL 13-4 " FOR 8 " WALL FL . JOIST 3 " x6 " LEDGER 4/8 " x8 " BOLTS 2-0 " C. TO C. 3/4 ...
... LINTELS - 2-1 / 2 " BARS , EXTEND 20 " BEYOND EDGE OF OPENING . MAX . SPAN 6 ' - 0 " STEEL LINTEL , ALTERNATE 20-0 " MAX . 18 " MIN . 9-0 " FOR 6 " WALL 13-4 " FOR 8 " WALL FL . JOIST 3 " x6 " LEDGER 4/8 " x8 " BOLTS 2-0 " C. TO C. 3/4 ...
Other editions - View all
Common terms and phrases
ALLOWABLE SPAN anchored applied approved attached backing BARS BEARING BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling chimney coat concrete construction Continued courses covered DESIGN DETAIL Direction ends exceed extend face Fasteners feet Figure finish coat fire fireplace FLASHING floor FOUNDATION four inches FRAMING furred gauge GRADE GROUP grout gypsum Gypsum Lath gypsum wallboard head HEADER height HOLLOW horizontal horizontal projection inches INSPECTION installed interior joints JOISTS laid least length less live load lumber masonry material maximum measured mesh Metal Lath mortar nails one-half opening partitions permit Perpendicular plaster PLATE portland cement pounds per square RAFTERS reinforced ROOF second coat Shakes sheathing side SOLID space SPAN specifically square feet Standard stone STORY stress studs Supporting surface Table thickness Type Uniform Building Code units veneer vertical Volume walls White width wire wood