Page 3
... building code . The material conforms to the 1967 Edition of the Uniform Building Code , Volume I , which is dedicated to the development of better building construction and greater safety to the public . The standards of safe ...
... building code . The material conforms to the 1967 Edition of the Uniform Building Code , Volume I , which is dedicated to the development of better building construction and greater safety to the public . The standards of safe ...
Page 12
... Uniform Building Code , Volume I , Tables No. 25 - U , No. 25 - V , and No. 25 - W give the maximum allowable spans for ceiling joists and roof rafters of a grade permitted by the Uniform Building Code as set forth in Table No. 25 - I ...
... Uniform Building Code , Volume I , Tables No. 25 - U , No. 25 - V , and No. 25 - W give the maximum allowable spans for ceiling joists and roof rafters of a grade permitted by the Uniform Building Code as set forth in Table No. 25 - I ...
Page 14
International Conference of Building Officials. TABLE NO . 25-1 ( Continued ) UNIFORM BUILDING SPECIES MINIMUM GRADE CODE STANDARD NUMBER GROUP IV ( Continued ) Fir , White Utility 25-3-67 25-4-67 Hemlock , West Coast Utility 25-3-67 ...
International Conference of Building Officials. TABLE NO . 25-1 ( Continued ) UNIFORM BUILDING SPECIES MINIMUM GRADE CODE STANDARD NUMBER GROUP IV ( Continued ) Fir , White Utility 25-3-67 25-4-67 Hemlock , West Coast Utility 25-3-67 ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP II GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles