... anchored . Concrete or masonry walls shall be anchored to all floors and roofs which provide lateral support for the wall or are required to provide stability for the wall . Such anchorage shall be capable of resisting a minimum ...
... anchored . Concrete or masonry walls shall be anchored to all floors and roofs which provide lateral support for the wall or are required to provide stability for the wall . Such anchorage shall be capable of resisting a minimum ...
Page 31
... Anchored Veneer Masonry and stone units [ five inches ( 5 ′′ ) maximum in thickness ] Masonry and Stone veneer not exceeding five inches ( 5 ′′ ) in thickness may be anchored directly to struc- tural masonry concrete or studs in one of ...
... Anchored Veneer Masonry and stone units [ five inches ( 5 ′′ ) maximum in thickness ] Masonry and Stone veneer not exceeding five inches ( 5 ′′ ) in thickness may be anchored directly to struc- tural masonry concrete or studs in one of ...
Page 32
... anchored directly to stud construction . The stud spacing shall not exceed sixteen inches ( 16 " ) on center . The galvanized wire mesh shall be anchored to wood studs by galvanized steel wire furring nails at four inches ( 4 " ) on ...
... anchored directly to stud construction . The stud spacing shall not exceed sixteen inches ( 16 " ) on center . The galvanized wire mesh shall be anchored to wood studs by galvanized steel wire furring nails at four inches ( 4 " ) on ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles