Page 31
... applied to the backing as a setting bed . The setting bed shall be a minimum of three - eighths inch ( % " ) thick and a maximum of three - fourths inch ( 4 " ) thick . A paste of neat portland cement or half portland cement and half ...
... applied to the backing as a setting bed . The setting bed shall be a minimum of three - eighths inch ( % " ) thick and a maximum of three - fourths inch ( 4 " ) thick . A paste of neat portland cement or half portland cement and half ...
Page 37
... applied over metal lath or wire lath and shall be not less than two coats when applied over other bases . Plaster shall not be applied directly to fiber insulation board . Portland cement plaster shall not be applied directly to gypsum ...
... applied over metal lath or wire lath and shall be not less than two coats when applied over other bases . Plaster shall not be applied directly to fiber insulation board . Portland cement plaster shall not be applied directly to gypsum ...
Page 39
... applied with suffi- cient material and pressure to form a complete key or bond . Gypsum plaster . For two - coat work , the first coat shall be brought out to grounds and straightened to a true surface leaving the surface rough to ...
... applied with suffi- cient material and pressure to form a complete key or bond . Gypsum plaster . For two - coat work , the first coat shall be brought out to grounds and straightened to a true surface leaving the surface rough to ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles