Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 7
Page 9
... attached thereto , and in no case shall be less than as set forth in Table No. 37 - A . [ Sec . 3702 ( f ) . ] Residential Fireplace2 TABLE NO . 37 - A - MINIMUM PASSAGEWAY AREAS FOR MASONRY CHIMNEYS ' TYPE OF MASONRY CHIMNEY MINIMUM ...
... attached thereto , and in no case shall be less than as set forth in Table No. 37 - A . [ Sec . 3702 ( f ) . ] Residential Fireplace2 TABLE NO . 37 - A - MINIMUM PASSAGEWAY AREAS FOR MASONRY CHIMNEYS ' TYPE OF MASONRY CHIMNEY MINIMUM ...
Page 25
... attached to sheathings other than wood shall be secured with approved mechan- ically - bonding nails or by approved corrosion - resistant nails on furring strips attached to the studs . Wood shingles or shakes may be applied over ...
... attached to sheathings other than wood shall be secured with approved mechan- ically - bonding nails or by approved corrosion - resistant nails on furring strips attached to the studs . Wood shingles or shakes may be applied over ...
Page 32
... attached to steel studs by equivalent wire ties . If this method is applied over solid sheathing , the mesh must be furred for embedment in grout . The wire mesh must be attached at the top and bot- tom with not less than 8 - penny ...
... attached to steel studs by equivalent wire ties . If this method is applied over solid sheathing , the mesh must be furred for embedment in grout . The wire mesh must be attached at the top and bot- tom with not less than 8 - penny ...
Other editions - View all
Common terms and phrases
ALLOWABLE SPAN anchored applied approved attached backing BARS BEARING BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling chimney coat concrete construction Continued courses covered DESIGN DETAIL Direction ends exceed extend face Fasteners feet Figure finish coat fire fireplace FLASHING floor FOUNDATION four inches FRAMING furred gauge GRADE GROUP grout gypsum Gypsum Lath gypsum wallboard head HEADER height HOLLOW horizontal horizontal projection inches INSPECTION installed interior joints JOISTS laid least length less live load lumber masonry material maximum measured mesh Metal Lath mortar nails one-half opening partitions permit Perpendicular plaster PLATE portland cement pounds per square RAFTERS reinforced ROOF second coat Shakes sheathing side SOLID space SPAN specifically square feet Standard stone STORY stress studs Supporting surface Table thickness Type Uniform Building Code units veneer vertical Volume walls White width wire wood