Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 11
Page 27
... backing . The distance between adjacent full- length headers shall not exceed twenty - four inches ( 24 " ) vertically or horizontally . Where the backing consists of two or more wythes the headers shall extend not less than four inches ...
... backing . The distance between adjacent full- length headers shall not exceed twenty - four inches ( 24 " ) vertically or horizontally . Where the backing consists of two or more wythes the headers shall extend not less than four inches ...
Page 29
... backing are completely separated except for the metal ties which serve as bonding . [ Sec . 2410 ( a ) . ] Construction In cavity walls neither the facing nor the backing shall be less than four inches ( 4 " ) in net thickness and the ...
... backing are completely separated except for the metal ties which serve as bonding . [ Sec . 2410 ( a ) . ] Construction In cavity walls neither the facing nor the backing shall be less than four inches ( 4 " ) in net thickness and the ...
Page 31
... backing . The resulting thickness of mortar in back of the units shall be not less than one - half inch ( 1⁄2 ... Backing may be of masonry , concrete or portland cement plaster on metal lath . Metal lath shall be fastened to the ...
... backing . The resulting thickness of mortar in back of the units shall be not less than one - half inch ( 1⁄2 ... Backing may be of masonry , concrete or portland cement plaster on metal lath . Metal lath shall be fastened to the ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles