Page 26
International Conference of Building Officials. inches ( 3 " ) in length upon solid masonry not less than four inches ( 4 " ) thick or upon a metal bearing plate of adequate design and dimensions to distribute the load safely on the wall ...
International Conference of Building Officials. inches ( 3 " ) in length upon solid masonry not less than four inches ( 4 " ) thick or upon a metal bearing plate of adequate design and dimensions to distribute the load safely on the wall ...
Page 27
... four inches ( 24 " ) vertically or horizontally . Where the backing consists of two or more wythes the headers shall extend not less than four inches ( 4 " ) into the most distant wythe or the backing wythes shall be bonded together ...
... four inches ( 24 " ) vertically or horizontally . Where the backing consists of two or more wythes the headers shall extend not less than four inches ( 4 " ) into the most distant wythe or the backing wythes shall be bonded together ...
Page 29
... four inches ( 34 " ) by lapping at least four inches ( 4 " ) over the unit below or by lapping at vertical intervals not exceeding seventeen inches ( 17 " ) with units which are at least 50 per cent greater in thickness than the units ...
... four inches ( 34 " ) by lapping at least four inches ( 4 " ) over the unit below or by lapping at vertical intervals not exceeding seventeen inches ( 17 " ) with units which are at least 50 per cent greater in thickness than the units ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles