Page 28
... laid up and grouted in lifts not to exceed six times the width of the grout space with a maximum of eight inches ( 8 ... laid in one - half - inch ( 1⁄2 " ) horizontal mortar joints and steel wire reinforcement may be laid in horizontal ...
... laid up and grouted in lifts not to exceed six times the width of the grout space with a maximum of eight inches ( 8 ... laid in one - half - inch ( 1⁄2 " ) horizontal mortar joints and steel wire reinforcement may be laid in horizontal ...
Page 44
... the label of an approved in- spection bureau or agency guaranteeing compliance with U.B.C. Standard No. 32-11-67 . [ Sec . 3203 ( d ) 7. ] All wood shingles shall be laid with a side lap 44 DWELLING HOUSE CONSTRUCTION.
... the label of an approved in- spection bureau or agency guaranteeing compliance with U.B.C. Standard No. 32-11-67 . [ Sec . 3203 ( d ) 7. ] All wood shingles shall be laid with a side lap 44 DWELLING HOUSE CONSTRUCTION.
Page 45
... laid with one and one - half - inch ( 11⁄2 " ) minimum side lap between joints in adjacent courses . Shakes shall be laid in straight or staggered courses with eighteen- inch ( 18 " ) wide strips of 30 - pound minimum felt shingled ...
... laid with one and one - half - inch ( 11⁄2 " ) minimum side lap between joints in adjacent courses . Shakes shall be laid in straight or staggered courses with eighteen- inch ( 18 " ) wide strips of 30 - pound minimum felt shingled ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles