Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 28
Page 7
... less than one - half the required area shall be openable . Required windows shall open directly onto a yard , public alley , or street either directly or through a porch with a min- imum clear height of not less than seven feet ( 7 ...
... less than one - half the required area shall be openable . Required windows shall open directly onto a yard , public alley , or street either directly or through a porch with a min- imum clear height of not less than seven feet ( 7 ...
Page 24
... less than one - half inch ( 1⁄2 " ) . Siding patterns known as rustic , drop siding , or shiplap shall have an average thickness in place of not less than nine- teen thirty - seconds inch ( 8 " ) and a minimum thickness of not less than ...
... less than one - half inch ( 1⁄2 " ) . Siding patterns known as rustic , drop siding , or shiplap shall have an average thickness in place of not less than nine- teen thirty - seconds inch ( 8 " ) and a minimum thickness of not less than ...
Page 37
... less than 18 gage wire . Exterior Surfaces All lath and lath attachments used on exterior exposed sur- faces shall be corrosion resistant . Building Paper Asphalt - saturated felt free from holes and breaks and weighing not less than 14 ...
... less than 18 gage wire . Exterior Surfaces All lath and lath attachments used on exterior exposed sur- faces shall be corrosion resistant . Building Paper Asphalt - saturated felt free from holes and breaks and weighing not less than 14 ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP III GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles