Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 13
Page 19
... Measured Along the Horizontal Projection ) RAFTER RAFTER ( Inches ) ( Inches ) Group II Group III Group IV2 12 10-0 9-0 7-0 4-0 16 9-0 7-6 6-0 3-6 2x 4 24 7-6 6-6 5-0 3-0 32 6-6 5-6 4-6 2-6 12 17-6 15-0 12-6 9-0 16 15-6 13-0 11-0 8-0 ...
... Measured Along the Horizontal Projection ) RAFTER RAFTER ( Inches ) ( Inches ) Group II Group III Group IV2 12 10-0 9-0 7-0 4-0 16 9-0 7-6 6-0 3-6 2x 4 24 7-6 6-6 5-0 3-0 32 6-6 5-6 4-6 2-6 12 17-6 15-0 12-6 9-0 16 15-6 13-0 11-0 8-0 ...
Page 24
... measured at the butt section of not less than seven - sixteenths inch ( " ) and a tip thickness of not less than three - sixteenths inch ( " ) . Siding of lesser dimen- sions may be used , provided the outside face of the stud is first ...
... measured at the butt section of not less than seven - sixteenths inch ( " ) and a tip thickness of not less than three - sixteenths inch ( " ) . Siding of lesser dimen- sions may be used , provided the outside face of the stud is first ...
Page 38
... measured from back plane of expanded metal lath , exclusive of ribs , or self - furring lath plaster thickness shall be three - fourths - inch ( 4 " ) minimum . No. 47 - E for gypsum plaster , and Table. PLASTER BASE Expanded Metal Lath ...
... measured from back plane of expanded metal lath , exclusive of ribs , or self - furring lath plaster thickness shall be three - fourths - inch ( 4 " ) minimum . No. 47 - E for gypsum plaster , and Table. PLASTER BASE Expanded Metal Lath ...
Other editions - View all
Common terms and phrases
ALLOWABLE SPAN anchored applied approved attached backing BARS BEARING BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling chimney coat concrete construction Continued courses covered DESIGN DETAIL Direction ends exceed extend face Fasteners feet Figure finish coat fire fireplace FLASHING floor FOUNDATION four inches FRAMING furred gauge GRADE GROUP grout gypsum Gypsum Lath gypsum wallboard head HEADER height HOLLOW horizontal horizontal projection inches INSPECTION installed interior joints JOISTS laid least length less live load lumber masonry material maximum measured mesh Metal Lath mortar nails one-half opening partitions permit Perpendicular plaster PLATE portland cement pounds per square RAFTERS reinforced ROOF second coat Shakes sheathing side SOLID space SPAN specifically square feet Standard stone STORY stress studs Supporting surface Table thickness Type Uniform Building Code units veneer vertical Volume walls White width wire wood