Uniform Building Code, Volume 6International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 21
Page 37
... PLASTERING General . Plastering with gypsum plaster or portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over other bases . Plaster ...
... PLASTERING General . Plastering with gypsum plaster or portland cement plaster shall be not less than three coats when applied over metal lath or wire lath and shall be not less than two coats when applied over other bases . Plaster ...
Page 38
... plaster thickness shall be three - fourths - inch ( 4 " ) minimum . No. 47 - E for gypsum plaster , and Table. PLASTER BASE Expanded Metal Lath Wire Lath Masonry Walls1 Monolithic Concrete Walls4 . 5 Monolithic Concrete Ceilings4.5 Gypsum ...
... plaster thickness shall be three - fourths - inch ( 4 " ) minimum . No. 47 - E for gypsum plaster , and Table. PLASTER BASE Expanded Metal Lath Wire Lath Masonry Walls1 Monolithic Concrete Walls4 . 5 Monolithic Concrete Ceilings4.5 Gypsum ...
Page 39
... plaster . The first two coats shall be as required for the first two coats of exterior plaster , except that the moist curing time period between the first and second coats shall be not less than 24 hours and the thickness shall be as ...
... plaster . The first two coats shall be as required for the first two coats of exterior plaster , except that the moist curing time period between the first and second coats shall be not less than 24 hours and the thickness shall be as ...
Other editions - View all
Common terms and phrases
ALLOWABLE SPAN anchored applied approved attached backing BARS BEARING BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling chimney coat concrete construction Continued courses covered DESIGN DETAIL Direction ends exceed extend face Fasteners feet Figure finish coat fire fireplace FLASHING floor FOUNDATION four inches FRAMING furred gauge GRADE GROUP grout gypsum Gypsum Lath gypsum wallboard head HEADER height HOLLOW horizontal horizontal projection inches INSPECTION installed interior joints JOISTS laid least length less live load lumber masonry material maximum measured mesh Metal Lath mortar nails one-half opening partitions permit Perpendicular plaster PLATE portland cement pounds per square RAFTERS reinforced ROOF second coat Shakes sheathing side SOLID space SPAN specifically square feet Standard stone STORY stress studs Supporting surface Table thickness Type Uniform Building Code units veneer vertical Volume walls White width wire wood