International Conference of Building Officials. Foundation Studs Foundation studs shall be not less in size than the studding above , and when exceeding four feet ( 4 ' ) in height shall be of the size required for an additional story ...
International Conference of Building Officials. Foundation Studs Foundation studs shall be not less in size than the studding above , and when exceeding four feet ( 4 ' ) in height shall be of the size required for an additional story ...
Page 31
... stud construction , the studs shall be spaced a maximum of sixteen inches ( 16 " ) on centers and approved paper shall first be applied over the sheathing or wires between studs and mortar shall be slushed into the one- inch ( 1 ...
... stud construction , the studs shall be spaced a maximum of sixteen inches ( 16 " ) on centers and approved paper shall first be applied over the sheathing or wires between studs and mortar shall be slushed into the one- inch ( 1 ...
Page 51
... STUDS 16 " C. TO C. FIRE STOPS AND PLATES OF 2 " MATERIAL DOUBLE PLATE of ZFIRE STOP AT COVE CEILING NOT MORE THAN S JOIST DEPTH 1 " x4 " RIBBON NAILED TO STUD CUT INTO STUD FIRE STOP 7-6 " MINIMUM CEILING HEIGHT 2014. TO C STUDS .2 ...
... STUDS 16 " C. TO C. FIRE STOPS AND PLATES OF 2 " MATERIAL DOUBLE PLATE of ZFIRE STOP AT COVE CEILING NOT MORE THAN S JOIST DEPTH 1 " x4 " RIBBON NAILED TO STUD CUT INTO STUD FIRE STOP 7-6 " MINIMUM CEILING HEIGHT 2014. TO C STUDS .2 ...
Other editions - View all
Common terms and phrases
11 gauge anchored applied approved Basecoat BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling concrete concrete masonry units Corbeling corrosion-resistant Direction 16 Douglas Fir exceed Expanded Metal Lath exterior walls Fasteners finish coat Fire-resistive Construction firebrick FIRESTOP five-eighths FLASHING FOUNDATION four inches FROST LINE GRADE GROUP II GROUP GROUTED MASONRY Gypsum Lath gypsum plaster gypsum wallboard HEADER Horizontal Perpendicular horizontal projection interior joints lath and plaster LINTEL MASONRY CHIMNEYS masonry walls MAXIMUM ALLOWABLE SPAN MAXIMUM SPACING mesh minimum modulus of elasticity mortar nails one-fourth inch one-half inch partitions plastered ceiling-not PLATE portland cement plaster pounds per square second coat sheathing six inches SOLID MASONRY square feet square foot square inch STORY stress-graded lumber studs Supporting Supporting Supporting Table thickness three-eighths inch twelve inches 12 twenty-four inches 24 U.B.C. Standard Uniform Building Code veneer Vertical Either Direction weatherboarding width wire lath wood frame wood shingles