... Surfaces All lath and lath attachments used on exterior exposed sur- faces shall be corrosion resistant . Building Paper Asphalt - saturated felt free from holes and breaks and weighing not less than 14 pounds per one hundred square ...
... Surfaces All lath and lath attachments used on exterior exposed sur- faces shall be corrosion resistant . Building Paper Asphalt - saturated felt free from holes and breaks and weighing not less than 14 pounds per one hundred square ...
Page 38
... surfaces may vary in plane , thickness of plaster need not be uniform . " When applied over a liquid bonding agent , finish coat may be applied directly to concrete surface . " Approved acoustical plaster may be applied directly to ...
... surfaces may vary in plane , thickness of plaster need not be uniform . " When applied over a liquid bonding agent , finish coat may be applied directly to concrete surface . " Approved acoustical plaster may be applied directly to ...
Page 39
... surface leaving the surface rough to receive the finish coat . For three- coat work , the surface of the first coat shall be scored suffi- ciently to provide adequate bond for the second coat and shall be permitted to harden and set ...
... surface leaving the surface rough to receive the finish coat . For three- coat work , the surface of the first coat shall be scored suffi- ciently to provide adequate bond for the second coat and shall be permitted to harden and set ...
Other editions - View all
Common terms and phrases
ALLOWABLE SPAN anchored applied approved attached backing BARS BEARING BOLTS bond Building Official CAVITY WALL Ceiling Ceiling Ceiling chimney coat concrete construction Continued courses covered DESIGN DETAIL Direction ends exceed extend face Fasteners feet Figure finish coat fire fireplace FLASHING floor FOUNDATION four inches FRAMING furred gauge GRADE GROUP grout gypsum Gypsum Lath gypsum wallboard head HEADER height HOLLOW horizontal horizontal projection inches INSPECTION installed interior joints JOISTS laid least length less live load lumber masonry material maximum measured mesh Metal Lath mortar nails one-half opening partitions permit Perpendicular plaster PLATE portland cement pounds per square RAFTERS reinforced ROOF second coat Shakes sheathing side SOLID space SPAN specifically square feet Standard stone STORY stress studs Supporting surface Table thickness Type Uniform Building Code units veneer vertical Volume walls White width wire wood